The Gate operation is a conditional pass-through.
When the gate is open, each data input is copied directly to its corresponding output.
When the gate is closed, all outputs retain their previous values and the execution path stops at this Node.
With the gate input unconnected the Gate always passes, and the Editor shows an info ring on that input saying so.
Inputs
Port
Type
Required
Description
> (Gate)
Any
No
Controls whether data passes through. When false or Nil, the operation is skipped and the path stops. See Gate Inputs.
In (variable, up to 20)
Any
Yes
Data inputs whose values are forwarded to corresponding outputs.
Outputs
Port
Type
Default
Description
(disabled port)
—
—
—
Out (variable, up to 20)
Mirrors paired input
Nil
Each output takes the type of the paired input; value is the input when the gate is open, previous value when closed.
Properties
Gate has no properties — its behaviour is entirely determined by whether the Gate Input is connected and what value it carries.
Its Node carries the On Error verb every fallible Operation carries — see the Error Handling guide.
State on Reload
All outputs are preserved across restarts within the configured time window.